Value of contrast-enhanced ultrasound for preoperative assessment of liver reserve function in patients with liver tumors.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Abstract:
      This study aimed to investigate the value of contrast-enhanced ultrasound (CEUS) for preoperative assessment of liver reserve function in patients with liver tumors. The indocyanine green (ICG) clearance tests and CEUS examinations of 45 noncirrhotic patients with liver tumors were performed prior to liver resection. Parameters time to peak (TtoPk), arrival time (Atm) as well as perfusion parameters A, k and A x k were generated from time-intensity curve (TIC) of CEUS. The correlation analyses of the ICG clearance per unit time (ICGK) and the retention rate at 15 min (ICGR15) with TtoPk, Atm, A, k and A x k were performed, and the diagnostic ability as well as optimal cut-off values of TtoPk and Atm for differentiating patients with ICGR15>10% from ICGR15<10% were analyzed. There were significant correlations of ICGK with TtoPk and Atm, and the correlation coefficients were 0.363 (p = 0.014) and -0.482 (p = 0.001), respectively. Significant correlations of ICGR15 with TtoPk and Atm were revealed, and the correlation coefficients were -0.416 (p = 0.004) and 0.303 (p = 0.043), respectively. No correlation of ICGK or ICGR15 with A, k and A x k was found in this study. There were significant differences in TtoPk and Atm between patients with ICGR15>10% and ICGR15<10% (p = 0.028 and p = 0.026, respectively). TtoPk and Atm both had good diagnostic abilities in diagnosing patients with ICGR15>10% verusus ICGR15<10% (AUROC = 0.711 and 0.721, respectively). For ICGR15>10% vs ICGR15, the optimal cut-off values of TtoPk and Atm were 13.307 s and 11.007 s, respectively, while the sensitivity and specificity were 75.0% and 72.7%, 60.6% and 75.0%, respectively. This study revealed that CEUS has the potential to be a new method to evaluate the liver reserve function of patients. With the optimal cut-off values of TtoPk and Atm, qualitative assessment of patients with ICGR15>10% could be more easily achieved by CEUS with good diagnostic abilities. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)