Evaluation and optimization of the extended information process unit (E-IPU) validation module integrating the sysmex flag systems and the recommendations of the French-speaking cellular hematology group (GFHC).

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Informa Healthcare Country of Publication: England NLM ID: 0404375 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1502-7686 (Electronic) Linking ISSN: 00365513 NLM ISO Abbreviation: Scand J Clin Lab Invest Subsets: MEDLINE
    • Publication Information:
      Publication: London : Informa Healthcare
      Original Publication: Oslo, Medisinsk Fysiologisk Forenings Forlag.
    • Subject Terms:
    • Abstract:
      The French-Speaking Cellular Haematology Group (GFHC) recently published criteria for microscopic analysis of a blood smears when a hemogram is requested. In order to evaluate and improve these recommendations using an XN (Sysmex) analyzer, we assessed 31,836 samples categorized into two sub-groups of patients either receiving or not receiving care in the clinical hematology/oncology departments of two university hospitals. By combining the manufacturer's recommendations and the GFHC recommendations, 21.3% of samples had a positive review flag in phase 1 of our study (17,991 samples). In phase 2 (13,845 samples), increasing the immature granulocytes (IG) percentage from 5-10% as a review trigger threshold, and ignoring slides with isolated flags 'PLT HIGH' (thrombocytosis) or 'MCV LOW' (microcytosis) or 'Blast/Abn Lymph and Atypical Lymph' (blast cells/abnormal lymphocytes and atypical lymphocytes) (in the absence of abnormal cells on a previous blood smear within 72 h), enabled us to significantly reduce the number of slides reviewed from 21.3-15.0% (p < 0.0001), without loss of clinical value. This decrease occurred in both sub-groups (hematology 48.7-38.0%, non-hematology 18.3-11.7%, p < 0.0001). In conclusion, the application of the GFHC criteria adapted to XN analyzers has enabled us to optimize the hematology laboratory processes, and thus reduce the production costs and the turnaround time of hemogram results.
    • Contributed Indexing:
      Keywords: Analytical techniques; automated blood counts; decision support systems; evidence-based laboratory medicine; hematologic diseases; hematology; laboratory management; laboratory routines and automation; laboratory standardization; management; medical biochemistry; microscopy
    • Publication Date:
      Date Created: 20160628 Date Completed: 20170324 Latest Revision: 20191210
    • Publication Date:
      20240104
    • Accession Number:
      10.1080/00365513.2016.1199049
    • Accession Number:
      27347841