Menu
×
Main Library
9 a.m. - 6 p.m.
Phone: (843) 805-6930
West Ashley Library
9 a.m. - 4 p.m.
Phone: (843) 766-6635
Folly Beach Library
Closed for renovations
Phone: (843) 588-2001
John L. Dart Library
9 a.m. - 6 p.m.
Phone: (843) 722-7550
St. Paul's/Hollywood Library
9 a.m. - 5 p.m.
Phone: (843) 889-3300
Mt. Pleasant Library
9 a.m. – 6 p.m.
Phone: (843) 849-6161
Dorchester Road Library
9 a.m. - 6 p.m.
Phone: (843) 552-6466
Edgar Allan Poe/Sullivan's Island Library
9 a.m. - 6 p.m.
Phone: (843) 883-3914
John's Island Library
9 a.m. - 6 p.m.
Phone: (843) 559-1945
McClellanville Library
Closed for renovations
Phone: (843) 887-3699
Edisto Library
9 a.m. - 3 p.m.
Phone: (843) 869-2355
Wando Mount Pleasant Library
9 a.m. - 6 p.m.
Phone: (843) 805-6888
Otranto Road Library
9 a.m. - 6 p.m.
Phone: (843) 572-4094
Hurd/St. Andrews Library
9 a.m. - 6 p.m.
Phone: (843) 766-2546
Baxter-Patrick James Island
9 a.m. - 6 p.m.
Phone: (843) 795-6679
Bees Ferry West Ashley Library
9 a.m. - 6 p.m.
Phone: (843) 805-6892
Village Library
9 a.m. - 6 p.m.
Phone: (843) 884-9741
Keith Summey North Charleston Library
9 a.m. – 6 p.m.
Phone: (843) 744-2489
Mobile Library
9 a.m. - 5 p.m.
Phone: (843) 805-6909
Today's Hours
Main Library
9 a.m. - 6 p.m.
Phone: (843) 805-6930
West Ashley Library
9 a.m. - 4 p.m.
Phone: (843) 766-6635
Folly Beach Library
Closed for renovations
Phone: (843) 588-2001
John L. Dart Library
9 a.m. - 6 p.m.
Phone: (843) 722-7550
St. Paul's/Hollywood Library
9 a.m. - 5 p.m.
Phone: (843) 889-3300
Mt. Pleasant Library
9 a.m. – 6 p.m.
Phone: (843) 849-6161
Dorchester Road Library
9 a.m. - 6 p.m.
Phone: (843) 552-6466
Edgar Allan Poe/Sullivan's Island Library
9 a.m. - 6 p.m.
Phone: (843) 883-3914
John's Island Library
9 a.m. - 6 p.m.
Phone: (843) 559-1945
McClellanville Library
Closed for renovations
Phone: (843) 887-3699
Edisto Library
9 a.m. - 3 p.m.
Phone: (843) 869-2355
Wando Mount Pleasant Library
9 a.m. - 6 p.m.
Phone: (843) 805-6888
Otranto Road Library
9 a.m. - 6 p.m.
Phone: (843) 572-4094
Hurd/St. Andrews Library
9 a.m. - 6 p.m.
Phone: (843) 766-2546
Baxter-Patrick James Island
9 a.m. - 6 p.m.
Phone: (843) 795-6679
Bees Ferry West Ashley Library
9 a.m. - 6 p.m.
Phone: (843) 805-6892
Village Library
9 a.m. - 6 p.m.
Phone: (843) 884-9741
Keith Summey North Charleston Library
9 a.m. – 6 p.m.
Phone: (843) 744-2489
Mobile Library
9 a.m. - 5 p.m.
Phone: (843) 805-6909
Patron Login
menu
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Unplanned Removal of Medical Devices in Critical Care Units in North West England Between 2011 and 2016.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- Author(s): Balmforth, Joanna E.; Thomas, Antony N.
- Source:
American Journal of Critical Care; May2019, Vol. 28 Issue 3, p213-221, 9p, 3 Charts, 3 Graphs- Subject Terms:
- Source:
- Additional Information
- Subject Terms:
- Abstract: Background The unplanned removal of medical devices poses a risk of harm to critically ill patients. Objective To determine rates, causes, and consequences of unplanned medical device removal, as well as factors mitigating harm to patients, in critical care units in the United Kingdom by reviewing patient safety incident reports. Methods Incidents of unplanned medical device removal in critical care units in North West England between 2011 and 2016 were retrospectively reviewed and classified. The incidents were classified by type of device displaced, staff and patient factors, causes and consequences of removal, and staff actions following removal. Displacement rates were calculated per 1000 patient days per unit. Results A total of 34 705 incident reports were reviewed, of which 1090 described unplanned device removal. The median rate of device removal was 0.7 (interquartile range, 0.4-2.2) per 1000 patient days per unit. Devices displaced most commonly included nasogastric tubes (317), central catheters (245), tracheostomy tubes (174), and endotracheal tubes (140). A total of 11 cardiac arrests were reported (8 associated with airway devices and 3 with central catheters). Factors contributing to displacement included initial placement (188), patient factors (563), and manual handling (238). Manual handling was cited in 49% of central catheter incidents and only 9% of nasogastric tube incidents. Patients' organic confusion was a factor in 16% of endotracheal tube and 80% of nasogastric tube removals. Conclusions Unplanned device removal may cause patient harm and is often preventable. The causes and consequences depend on the type of device removed. [ABSTRACT FROM AUTHOR]
- Abstract: Copyright of American Journal of Critical Care is the property of American Association of Critical-Care Nurses and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Contact CCPL
Copyright 2022 Charleston County Public Library Powered By EBSCO Stacks 3.3.0 [350.3] | Staff Login
No Comments.