Design and verification of a shape memory polymer peripheral occlusion device.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Elsevier Country of Publication: Netherlands NLM ID: 101322406 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1878-0180 (Electronic) Linking ISSN: 18780180 NLM ISO Abbreviation: J Mech Behav Biomed Mater Subsets: MEDLINE
    • Publication Information:
      Original Publication: Amsterdam : Elsevier
    • Subject Terms:
    • Abstract:
      Shape memory polymer foams have been previously investigated for their safety and efficacy in treating a porcine aneurysm model. Their biocompatibility, rapid thrombus formation, and ability for endovascular catheter-based delivery to a variety of vascular beds makes these foams ideal candidates for use in numerous embolic applications, particularly within the peripheral vasculature. This study sought to investigate the material properties, safety, and efficacy of a shape memory polymer peripheral embolization device in vitro. The material characteristics of the device were analyzed to show tunability of the glass transition temperature (Tg) and the expansion rate of the polymer to ensure adequate time to deliver the device through a catheter prior to excessive foam expansion. Mechanical analysis and flow migration studies were performed to ensure minimal risk of vessel perforation and undesired thromboembolism upon device deployment. The efficacy of the device was verified by performing blood flow studies that established affinity for thrombus formation and blood penetration throughout the foam and by delivery of the device in an ultrasound phantom that demonstrated flow stagnation and diversion of flow to collateral pathways.
      (Copyright © 2016 Elsevier Ltd. All rights reserved.)
    • References:
      Thromb Haemost. 1995 Jan;73(1):66-72. (PMID: 7740499)
      Cardiovasc Intervent Radiol. 2013 Aug;36(4):1006-14. (PMID: 23456353)
      J Vet Cardiol. 2012 Sep;14(3):431-44. (PMID: 22885114)
      AJNR Am J Neuroradiol. 2002 Oct;23(9):1580-8. (PMID: 12372752)
      J Vasc Interv Radiol. 2010 Dec;21(12):1873-7. (PMID: 20974540)
      Cardiovasc Intervent Radiol. 2011 Jun;34(3):522-31. (PMID: 20700592)
      J Neurol Sci. 2009 Jul 15;282(1-2):21-7. (PMID: 19144359)
      J Vet Intern Med. 2014 Sep-Oct;28(5):1504-12. (PMID: 25041218)
      Smart Mater Struct. 2011 Aug 1;20(8):. (PMID: 21949469)
      Pflugers Arch. 1976 Mar 30;362(2):201-2. (PMID: 944427)
      Macromol Chem Phys. 2014 Dec;215(24):2420-2429. (PMID: 30220825)
      Urol Clin North Am. 2014 Feb;41(1):129-44. (PMID: 24286772)
      Acta Radiol. 2013 Sep;54(7):790-4. (PMID: 23535183)
      Trans Am Soc Artif Intern Organs. 1974;20 B:449-55. (PMID: 4141527)
      Vet Clin Pathol. 1979;8(1):31-3. (PMID: 15314780)
      Ann Biomed Eng. 2012 Apr;40(4):883-97. (PMID: 22101759)
      Vasc Endovascular Surg. 2014 Oct-Nov;48(7-8):516-21. (PMID: 25487250)
      PLoS One. 2014 Nov 05;9(11):e109997. (PMID: 25372784)
      J Biomech Eng. 2004 Aug;126(4):529-35. (PMID: 15543873)
      J Neurosurg. 1999 Aug;91(2):284-93. (PMID: 10433317)
      Ann Epidemiol. 2005 Mar;15(3):175-84. (PMID: 15723761)
      J Gen Intern Med. 1997 Jun;12(6):374-83. (PMID: 9192256)
      Biomaterials. 2009 Mar;30(8):1542-50. (PMID: 19111338)
      Am J Clin Pathol. 1997 Jan;107(1):105-10. (PMID: 8980376)
      J Biomed Mater Res A. 2014 May;102(5):1231-42. (PMID: 23650278)
      Turk Kardiyol Dern Ars. 2015 Jun;43(4):376-80. (PMID: 26142793)
      Microvasc Res. 2003 Jul;66(1):59-67. (PMID: 12826075)
      J Endovasc Ther. 2005 Aug;12(4):486-94. (PMID: 16048381)
      Ann Biomed Eng. 2013 Apr;41(4):725-43. (PMID: 23329002)
      Cardiovasc Intervent Radiol. 2010 Aug;33(4):844-8. (PMID: 19908084)
      J Polym Sci B Polym Phys. 2012 May 15;50(10):724-737. (PMID: 22570509)
      J Neurosurg. 1995 Jul;83(1):129-32. (PMID: 7782828)
      Interact Cardiovasc Thorac Surg. 2013 Nov;17(5):882-5. (PMID: 23868605)
      AJR Am J Roentgenol. 2009 Mar;192(3):793-9. (PMID: 19234279)
      Cardiovasc Intervent Radiol. 2011 Feb;34(1):74-80. (PMID: 20390272)
      J Mech Behav Biomed Mater. 2014 Dec;40:102-114. (PMID: 25222869)
    • Grant Information:
      R01 EB000462 United States EB NIBIB NIH HHS; R43 EB022016 United States EB NIBIB NIH HHS; R44 EB022016 United States EB NIBIB NIH HHS
    • Contributed Indexing:
      Keywords: Embolization; Pelvic congestion syndrome; Shape memory polymer; Varicocele; Varicose veins
    • Accession Number:
      0 (Biocompatible Materials)
      0 (Polymers)
    • Publication Date:
      Date Created: 20160716 Date Completed: 20171206 Latest Revision: 20231112
    • Publication Date:
      20231112
    • Accession Number:
      PMC5508979
    • Accession Number:
      10.1016/j.jmbbm.2016.06.019
    • Accession Number:
      27419615