Pilot Validation of Ambulatory Activity Monitors for Sleep Measurement in Huntington's Disease Gene Carriers.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Abstract:
      Sleep disturbance occurs early in Huntington's disease (HD). Consumer and research-grade activity monitors may enable routine assessment of sleep disturbances in HD.We compared Actiwatch Spectrum Pro, Jawbone UP2 and Fitbit One to the gold standard, polysomnography, in four late presymptomatic and three early HD participants. Compared to polysomnography, all ambulatory monitors overestimated total sleep time by >60 minutes and sleep efficiency by ∼15%. Thus, for assessment of specific sleep parameters in HD, none of the activity monitors are sufficiently accurate to replace polysomnography, although they may be sufficient for estimating overall sleep-wake patterns. Larger sample replication is required. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Journal of Huntington's Disease is the property of IOS Press and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)